CLD 14 concists of a bitumen mat with self adhesive and paper release on both sides. Comes in 2 thicknesses; 1,4 mm and 2,1 mm. CLD sheets are primarly used for attenuation of radiation of structureborne noise in mechanical structures. Can be used in various applications with plywood, steel or aluminium base plates. Usually recommended for stiff structural applications, where unconstrained damping is unsufficient. Energy is dissipated as a result of shear deformation in the damping layer.
Material should have room temperature when cutting and during installation.
Light weight applications: Ventilation ducts, cabinets, noise enclusures, cabins.
Heavy duty applications: Bulkhead isolation, heavy constructions, thick steel panels. Wind-turbine generators, Marine & Offshore
Characteristics
Thickness:
1.4: 1.4 ± 0.2 mm
2.1: 2.1 ± 0.3 mm
Sheet dimension:
1020 mm x1020 mm (standard)
Custom dimensions and cut on request
Surface weight:
1.4: 1.3 kg/m² (+0.25 / -0.13 kg/m²)
2.1: 2.0 kg/m² (± 0.2 kg/m²)
Adhesion:
Initial adhesive force: Min. 6 N/50 mm according to TM 206
Ultimate strenght: Min. 70 N/ 50 mm according to TM 214
Fire resistance:
< 75 mm/ min according to FMVSS 302
Temperature range:
-30 ° C- + 90 ° C
Notes
Storage:
Max. 6 months in tempererature 0 ° C – + 30 ° C
Tolerances:
Raw format – 0
Cutting ± 5 mm
Punch ± 2 mm